Preregistration

Preregistration: Using a test battery to compare three remote, video-based eye-trackers (comparET)

Author(s) / Creator(s)

Spitzer, Lisa
Mueller, Stefanie

Abstract / Description

Eye-tracking research is based on data collected with a multitude of eye-tracking devices. The comparability of results obtained by different devices is unclear. This study aims to investigate the comparability of data of three remote eye-tracking devices, the Gazepoint GP3HD Desktop, the Tobii Pro X3-120, and the EyeLink 1000+, using an extensive test battery. Data of N = 25 participants will be collected, who will be recruited by subject pool advertisement, email lists, and personal invitation. Inclusion criteria comprise a successful calibration with all three eye-tracking devices. Participants will receive monetary compensation. Participants will complete eight eye-movement tasks, consecutively measured by each eye-tracker. The tasks measure various eye-tracking parameters, such as accuracy, precision, smooth pursuit, microsaccades, or pupil dilation. The measure of data quality obtained in each task, will be compared between devices.
This is a preregistration of the article: Spitzer, L., & Mueller, S. (2022). Using a test battery to compare three remote, video-based eye-trackers. In 2022 Symposium on Eye Tracking Research and Applications (ETRA '22). Association for Computing Machinery, New York, NY, USA, Article 28, 1–7. https://doi.org/10.1145/3517031.3529644

Keyword(s)

reproducibility eye-tracking Tobii Gazepoint EyeLink

Persistent Identifier

PsychArchives acquisition timestamp

2021-09-17 20:11:01 UTC

Publisher

PsychArchives

Citation

Spitzer, L., & Mueller, S. (2021). Preregistration: Using a test battery to compare three remote, video-based eye-trackers (comparET). PsychArchives. https://doi.org/10.23668/PSYCHARCHIVES.5111
  • Author(s) / Creator(s)
    Spitzer, Lisa
  • Author(s) / Creator(s)
    Mueller, Stefanie
  • PsychArchives acquisition timestamp
    2021-09-17T20:11:01Z
  • Made available on
    2021-09-17T20:11:01Z
  • Date of first publication
    2021-09-17
  • Abstract / Description
    Eye-tracking research is based on data collected with a multitude of eye-tracking devices. The comparability of results obtained by different devices is unclear. This study aims to investigate the comparability of data of three remote eye-tracking devices, the Gazepoint GP3HD Desktop, the Tobii Pro X3-120, and the EyeLink 1000+, using an extensive test battery. Data of N = 25 participants will be collected, who will be recruited by subject pool advertisement, email lists, and personal invitation. Inclusion criteria comprise a successful calibration with all three eye-tracking devices. Participants will receive monetary compensation. Participants will complete eight eye-movement tasks, consecutively measured by each eye-tracker. The tasks measure various eye-tracking parameters, such as accuracy, precision, smooth pursuit, microsaccades, or pupil dilation. The measure of data quality obtained in each task, will be compared between devices.
    en
  • Abstract / Description
    This is a preregistration of the article: Spitzer, L., & Mueller, S. (2022). Using a test battery to compare three remote, video-based eye-trackers. In 2022 Symposium on Eye Tracking Research and Applications (ETRA '22). Association for Computing Machinery, New York, NY, USA, Article 28, 1–7. https://doi.org/10.1145/3517031.3529644
    en
  • Publication status
    other
    en
  • Review status
    unknown
    en
  • Citation
    Spitzer, L., & Mueller, S. (2021). Preregistration: Using a test battery to compare three remote, video-based eye-trackers (comparET). PsychArchives. https://doi.org/10.23668/PSYCHARCHIVES.5111
    en
  • Persistent Identifier
    https://hdl.handle.net/20.500.12034/4534
  • Persistent Identifier
    https://doi.org/10.23668/psycharchives.5111
  • Language of content
    eng
  • Publisher
    PsychArchives
    en
  • Is related to
    https://doi.org/10.1145/3517031.3529644
  • Keyword(s)
    reproducibility
    en
  • Keyword(s)
    eye-tracking
    en
  • Keyword(s)
    Tobii
    en
  • Keyword(s)
    Gazepoint
    en
  • Keyword(s)
    EyeLink
    en
  • Dewey Decimal Classification number(s)
    150
  • Title
    Preregistration: Using a test battery to compare three remote, video-based eye-trackers (comparET)
    en
  • DRO type
    preregistration
    en
  • Visible tag(s)
    PRP-QUANT
    en